WFWG May Hang Loading in Enhanced Mode Without a Terminator

Last reviewed: November 21, 1994
Article ID: Q93478
The information in this article applies to:
  • Microsoft Windows for Workgroups versions 3.1, 3.11

SYMPTOMS

  • Windows for Workgroups stops responding (hangs) at the logo screen when starting in 386 enhanced mode.

    -or-

  • Windows for Workgroups hangs after the logo screen when starting in standard mode if the real-mode redirector has been started.

    -or-

  • The computer may stop responding in MS-DOS if a NET USE or NET VIEW command is used.
  • Your system stops responding (hangs) when you attempt to exit Windows for Workgroups.

CAUSE

This problem occurs when there is no terminator connected to the network interface card (NIC). The NIC requires a terminator even if the card isn't on the network. The Intel EtherExpress 16, which is shipped with some versions of Windows for Workgroups, requires a terminator if it is configured with Thin Ethernet cable. The 3Com EtherLink III card also requires a terminator.

WORKAROUND

To work around this problem, attach a terminator to the coaxial jack on the network card. Or, if you are using the Intel EtherExpress 16 card, use the appropriate procedure below.

Windows for Workgroups 3.1

  1. Start Windows for Workgroups in standard mode by typing:

          win/s
    

  2. From Control Panel, choose the Network icon.

  3. Choose the Adapters button and select the Intel EtherExpress 16.

  4. Choose the Advanced button and select Transceiver Type.

  5. In the Transceiver Type field, select Thick Net (AUI/DIX).

  6. Choose OK, then choose Close until you are back in Control Panel.

Windows for Workgroups 3.11

  1. Start Windows for Workgroups without loading the network software by typing:

          win /n
    

  2. From the Program Manager Network group, run Network Setup.

  3. Choose the Drivers button.

  4. Select Intel EtherExpress 16 and choose the Advanced button.

  5. Select Transceiver Type.

  6. In the Transceiver Type field, select Thick Net (AUI/DIX) and then choose the Set button.

  7. Choose OK twice.

MORE INFORMATION

The Windows for Workgroups add-on user kit does not ship with a terminator. Normally, the add-on user kit is installed on an existing, functional Windows for Workgroups network. Because a functional Windows for Workgroups network must be already terminated on both ends, it is not necessary to provide an additional terminator to add a new user.


KBCategory: kbnetwork kbprb kb3rdparty
KBSubcategory: win31 wfw wfwg
Additional reference words: 3.10 3.11 ether express ee16 lock up lockup
lock-up crash freeze hang


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.