SYMPTOMS

The COMSPEC environment variable is not set after Windows 95 has started.

CAUSE

This environment variable is not set if you are using J.P. Software 4DOS.COM instead of MS-DOS COMMAND.COM on the SHELL line in your CONFIG.SYS file.

RESOLUTION

To correct this problem:

  • Upgrade to 4DOS version 4.02 or later.

    -or-

  • Set the COMSPEC variable in the AUTOEXEC.BAT file by adding the following statement to the AUTOEXEC.BAT file

          set comspec=c:\<directory name>\4dos.com
    

    where <directory name> is the directory in which you installed 4DOS.

    -or-

  • Use COMMAND.COM, in place of 4DOS.COM, on the SHELL statement in your CONFIG.SYS file.

MORE INFORMATION

4DOS is manufactured by J.P. Software, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.


KBCategory: kbenv kb3rdparty kbprb
KBSubcategory: wpp95 win95 appscomp diskmem
Additional reference words: 95 fourdos 4 dos 3rdparty


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: September 13, 1995
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.