Connectoid's Associated Script File Does Not Run

Last reviewed: March 13, 1996
Article ID: Q140684
The information in this article applies to:
  • Microsoft Windows 95
  • Microsoft Plus! for Windows 95

SYMPTOMS

When you associate a script file with a Dial-Up Networking connectoid using the Dial-Up Scripting Tool included with Microsoft Plus!, the script file may not run when you double-click the connectoid.

CAUSE

This behavior can occur if the Dial-Up Networking connectoid that the script file is associated with is configured to open a terminal window after dialing. When a connectoid is configured to open a terminal window after dialing, an associated script file does not run.

RESOLUTION

Configure the connectoid so that a terminal window is not opened after dialing. To do so, follow these steps:

  1. Use the right mouse button to click the connectoid, and then click Properties on the menu that appears.

  2. Click Configure, and then click the Options tab.

  3. Click the "Bring up terminal window after dialing" check box to clear it, and then click OK.


KBCategory: kbtool
KBSubcategory: win95 winplus wincomm dun
Additional reference words: 95


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: March 13, 1996