SBS Install Hangs Computer with Dial-Up Networking and MSDLC32Last reviewed: October 31, 1996Article ID: Q142985 |
The information in this article applies to:
SYMPTOMSAfter you install Windows 95 to a local hard disk from a server-based installation of Windows 95, your computer may stop responding (hang) when Setup tries to restart the computer.
CAUSEThe Msbatch.inf file has Dial-Up Networking chosen, and MSDLC32 has been added using Infinst.exe. The dial-up adapter does not bind to MSDLC32.
RESOLUTIONAdd the following line to the [Network] section of the Msbatch.inf file:
RemoveBinding=msdlc32,*PNP8387 |
KBCategory: kbnetwork kbsetup