SBS Install Hangs Computer with Dial-Up Networking and MSDLC32

Last reviewed: October 31, 1996
Article ID: Q142985
The information in this article applies to:
  • Microsoft Windows 95

SYMPTOMS

After you install Windows 95 to a local hard disk from a server-based installation of Windows 95, your computer may stop responding (hang) when Setup tries to restart the computer.

CAUSE

The Msbatch.inf file has Dial-Up Networking chosen, and MSDLC32 has been added using Infinst.exe. The dial-up adapter does not bind to MSDLC32.

RESOLUTION

Add the following line to the [Network] section of the Msbatch.inf file:

   RemoveBinding=msdlc32,*PNP8387


KBCategory: kbnetwork kbsetup
KBSubcategory: win95
Additional reference words: 95


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: October 31, 1996