Windows 95 OEM Service Release 2 CD-ROM Network.txt File

Last reviewed: December 15, 1997
Article ID: Q160507
The information in this article applies to:
  • Microsoft Windows 95 OEM Service Release 2

IMPORTANT: This article contains information about editing the registry. Before you edit the registry, you should first make a backup copy of the registry files (System.dat and User.dat). Both are hidden files in the Windows folder.

WARNING: Using Registry Editor incorrectly can cause serious problems that may require you to reinstall Windows 95. Microsoft cannot guarantee that problems resulting from the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk.

NOTE: For information about how to edit the registry, view the Changing Keys And Values online Help topic in Registry Editor (Regedit.exe). Note that you should make a backup copy of the registry files (System.dat and User.dat) before you edit the registry.

SUMMARY

This article contains a copy of the information in the Network.txt file from the Windows 95 OEM Service Release 2 (OSR2) CD-ROM. Setup copies this file to the Windows folder.

MORE INFORMATION

       -----------------------------------------------------------
                    Microsoft Windows 95 README for Networks
                                   August 1996
       -----------------------------------------------------------

                    (c) Copyright Microsoft Corporation, 1996


This document provides complementary or late-breaking information to supplement the Microsoft Windows 95 documentation.

HOW TO USE THIS DOCUMENT

To view Networks.txt on screen in Notepad, maximize the Notepad window.

To print Networks.txt, open it in Notepad or another word processor, and then use the Print command on the File menu.

CONTENTS

CLIENT FOR NETWARE

  Windows 95 and NetWare 3.12 and 4.01 Servers
  Opening Files on NetWare 3.11 Servers
  Lowercase Extended-Character Passwords on NetWare 4.1 Servers
  Client for NetWare and Programs That Use External Files
  Novell NetWare Login Scripts
  Installing Novell Client32 Overwrites
    NetWare Directory Services Files
  Upgrading Over an Earlier Beta Version of Windows
  Printing to NetWare Directory Services Printers
PLUG AND PLAY NETWORK CARDS AND 16-BIT REAL-MODE DRIVERS INTEL ETHEREXPRESS 16 NICs AND PCI COMPUTERS WINDOWS FOR WORKGROUP SHARES RUNNING WINDOWS 95 FROM A SERVER
  To Install Windows 95 over Previous Builds
SUPPORT FOR THIRD-PARTY NETWORKS
  LANDESK 2.0
  SunSelect PC-NFS
  Banyan VINES
  DEC Pathworks
  Artisoft LANtastic
PRINTING TO A NETWORK PRINTER PROBLEMS PRINTING TO POSTSCRIPT PRINTERS OVER A NETWARE NETWORK ISSUES AND INSTALLATION OF MS-DLC WITH WINDOWS 95 MICROSOFT TCP/IP PROTOCOL USER PROFILES OVER THE NETWORK NETWORK BACKUP AGENTS
  Arcada Backup Exec Network Backup Agent
  Cheyenne ARCserve Network Backup Agent
REAL-MODE PROTOCOLS: WARNING ICONS ON YOUR NETWORK ADAPTER USING AN IBM THINKPAD WITH A DOCK II INTEL ETHEREXPRESS PRO /100B CARD NOT CORRECTLY DETECTED SETTING UP A WINS SERVER INTERLNK USING COMSPEC VARIABLES POINTING TO NETWORK COMMAND.COM FILES

CLIENT FOR NETWARE

Windows 95 and NetWare 3.12 and 4.01 Servers

Windows 95 with Microsoft Client for NetWare can experience problems with NetWare 3.12 and 4.01 servers if packet burst is turned on. This is a known problem with these servers that Novell has fixed and posted on their forums. Download the file Pburst.exe from the Novell NetWare Forum on Compuserve or the Novell Web site (Ftp.Novell.com).

Pburst.exe contains the patch for the affected servers.

Opening Files on NetWare 3.11 Servers

Programs that open a large number of files consecutively in rapid succession might have occasional problems opening files on NetWare 3.11 servers. This can also happen when opening a file in a folder for which you do not have file scan rights, such as an MS Mail shared post office.

Possible error messages:

- "File not found" error on a file you know exists - "Sharing violation" or "Lock violation" error - "Unable to open file" error - "File in use" error

There are two solutions to these problems:

- Obtain a patch file from Novell for the NetWare 3.11 server. Using

  FTP, connect to ftp.novell.com. Go to /pub/netware/nwos/nw311/osnlm
  and run 311ptd.exe. This program will extract the file os2opnfx.nlm.
  Then, load the .nlm file onto the NetWare 3.11 server.
  ("load os2opnfx.nlm")

- Disable long filename support in Client for NetWare. This means that
  you will not be able to use long filenames on any NetWare servers
  from Windows 95. To disable long-filename support, carry out the
  following steps:

  1. Click the Start menu, click Run, and then type Regedit.
  2. Go to
     HKEY_Local_Machine\System\CurrentControlSet\Services\VxD\NWRedir
  3. Create a new binary value named supportLFN with a value of 0.

Lowercase Extended-Character Passwords on NetWare 4.1 Servers

In a NetWare 4.1 environment, Client for NetWare does not support passwords that use certain lowercase extended characters. Users need to change their password to all uppercase characters.

Client for NetWare and Programs That Use External Files

If you are using Microsoft Client for NetWare, and you run a program that needs to access an auxiliary file, your program will have problems if the auxiliary file is on a drive other than the one the program is on. This is because only the current drive is searched for auxiliary files; the search path is not searched. If you experience this problem, make sure the program and any auxiliary files are on the same drive.

Novell NetWare Login Scripts

The Login Script Processor for the Microsoft Client for NetWare should correctly process all commands in your login scripts. However, you cannot load memory-resident programs (TSRs) from these scripts.

Installing Novell Client32 Overwrites NetWare Directory Services Files When you install Novell Client32, the Novell setup program replaces the Microsoft file Netdef.inf and renames it Netdef.bnw, and deletes the NDS setup file Nwnds.dll. The result is that after uninstalling Novell Client32, Service for NetWare Directory Services will not install.

To work around this problem, carry out the following steps:

  1. Find the file Netdef.bnw and rename it Netdef.inf.

  2. Copy the Nwnds.dll file to the Windows\System directory on your your hard disk by carrying out the following procedure:

    1. Insert your Windows 95 installation CD into the CD-ROM drive. 2. Open an MS-DOS window. 3. Change to the Win95 directory on your CD-ROM, and then type the

          following at the command prompt:
    

          extract /l c:\windows\system precopy2.cab nwnds.dll
    

Upgrading Over an Earlier Beta Version of Windows

If you upgrade this release of Windows over an earlier beta release, and you have Service for NetWare Directory Services installed, you will be prompted about version conflicts for the following files:

- Nwnp32.dll (v. 4.0.969) - Nwlsproc.exe (v. 4.0.968) - Netware.tmp (v. 4.0.968)

When you see the version conflict prompt, click No. After Windows is installed, you need to reinstall Service for NetWare Directory Services. To do this, carry out the following steps:

  1. In Control Panel, double-click the Network icon.
2. Click Add, click Service, and then click Add. 3. Follow the instructions on your screen.

Printing to NetWare Directory Services Printers

You cannot install Client for NetWare Networks and Service for NetWare Directory Services (NDS) during the same installation session. If you do, your NDS printers will appear to be offline.

If your printers appear to be offline, try carrying out the following steps:

  1. In Control Panel, double-click the Network icon.
2. Remove both Client for NetWare Networks and Service for NDS. 3. Restart your computer. 4. In Control Panel, double-click the Network icon. 5. Add Service for NDS. 6. Restart your computer.

NOTE: If your local area network is using NetWare 4.1 or later, there is no need to install Client for NetWare Networks separately. When you install Service for NDS, it also installs the Client for NetWare Networks.

PLUG AND PLAY NETWORK CARDS AND 16-BIT REAL-MODE DRIVERS

When you run the 16-bit real-mode driver for your Plug and Play network interface card (NIC), your Plug and Play card might appear not to function.

The reason the card appears to malfunction is that on most computers, the Plug and Play card is inactive until Windows 95 enables it. 16-bit NIC drivers load before Windows 95 can turn on Plug and Play cards. Some 16-bit NIC drivers do not recognize Plug and Play cards (most NE2000 Plug and Play clones fall into this category). In this case, follow these steps to use your Plug and Play card with a 16-bit NIC driver:

  1. Run the Softset utility that comes with your Plug and Play card, and then set the card to non-Plug and Play mode.
2. Remove the network card from the list of devices in the Device
   Manager listing: In Control Panel, double-click the System icon,
   click the Device Manager tab, select the network card, and then
   click Remove.
3. Reinstall the network card using the Add New Hardware icon in
   Control Panel.

When you install a 32-bit protect mode NIC driver in the future, you can rerun Softset to turn on Plug and Play mode for your card. This problem does not happen if you are using a 32-bit protect-mode NIC driver.

INTEL ETHEREXPRESS 16 NICs AND PCI COMPUTERS

If you are using an Intel EtherExpress 16-network interface card (NIC) in a PCI computer that has a Diamond Speed Star PCI video card, your system might hang or not initialize properly. These problems, according to Intel customer support, are not related to Windows 95 and happen on a variety of operating systems.

If you have one of the following video cards, contact your vendor to obtain a new video BIOS update:

   * Diamond Speed Star PCI video card with BIOS version 1.01
   * Diamond Viper PCI VGA Video Adapter
   * Diamond Stealth video card, BIOS v1.03

Other PCI video cards might also cause problems with this Intel NIC. In general, if you experience problems with your EtherExpress 16 in a PCI computer other than those described above, please replace the card before reporting the problem to Microsoft.

WINDOWS FOR WORKGROUP SHARES

When you upgrade to Windows 95 from Windows for Workgroups, your shares are not maintained. The folders/directories you shared in Windows for Workgroups need to be reshared.

RUNNING WINDOWS 95 FROM A SERVER

Windows 95 can be set up to run from a network server. The Windows 95 Resource Kit contains complete instructions for installing Windows in this environment (see Chapter 4, "Server Based Setup for Windows 95").

The following configurations are supported:

- Booting from hard disk using:

  - Client for Microsoft Networks
  - Client for NetWare Networks
  - Novell Workstation Shell 3.x (NETX)
  - Novell Workstation Shell 4.x (VLM)
  - Banyan VINES DOS/Windows client

- Booting from a floppy disk using:
  - Client for Microsoft Networks
  - Client for NetWare Networks
  - Novell Workstation Shell 3.x (NETX)
  - Novell Workstation Shell 4.x (VLM)
  - Banyan VINES DOS/Windows client

- Booting from a remote boot server using:
  - Client for NetWare Networks
  - Novell Workstation Shell 3.x (NETX)
  - Novell Workstation Shell 4.x (VLM)

To use one of the Microsoft clients, your network card must have both an NDIS2 (16-bit real mode) *AND* an NDIS3 (32-bit protect mode) driver. If your network card is a PCI, EISA, or ISAPNP card, you must run Windows over a real-mode client.

To Install Windows 95 over Previous Builds

To install this final version of Windows 95 on network computers that are already running Windows 95, you have two choices:

- Do a clean install on each computer;

  -or-
- Upgrade each computer using the following procedure:

  1. Shut down any clients running from the server.
  2. Windows 95 must be installed on the server into the same folder
     that you were using for previous builds. Delete everything in the
     shared Windows 95 folder, and then run Netsetup.exe to install this
     build into that folder.
  3. Restart the client to a command prompt.
  4. If you are using the Microsoft Client for NetWare Networks and use
     map rooted  drives, you must start either NETX or VLM to run Setup.
  5. Map drives to the machine folder and shared Windows 95 folder
     as before. These must use the same drive letters as used in the
     previous build, and map roots should be to the same folder level.
  6. Run Setup for the new build.

SUPPORT FOR THIRD-PARTY NETWORKS

To install support for a third-party, real-mode network, you must be running the network when you run Windows 95 Setup. Windows 95 does not support installation of a real-mode network after Setup, unless you have a Windows 95-specific .inf file from your network vendor. For example, FTP includes a Windows 95 .inf in their 32-bit NFS client. Although Windows 95 supports other networks, network component files for networks other than Microsoft networks are not included with Windows 95. You must already have the files for the network you want to install.

LANDESK 2.0

LANDESK version 2.0 uses a TSR named Usertsr.exe that might cause Windows 95 to stop responding when you use the Microsoft IPX/SPX- compatible protocol (Nwlink.vxd) or file and printer sharing for Microsoft Networks (Vserver.vxd).

LANDESK version 2.01 fixes this problem, and the patch is available on Intel's BBS or from Intel product support. For the BBS and product support telephone numbers, consult the documentation that came with your copy of LANDESK.

SunSelect PC-NFS

Windows 95 supports versions 5.0 or greater of SunSelect PC-NFS. If SunSelect PC-NFS is installed using an NDIS 2 LAN driver or an ODI LAN driver, then SunSelect PC-NFS can be installed as an additional 16-bit network client along with 32-bit protected-mode clients. If you are using a SunSelect PC-NFS LAN Driver, Windows 95 can support PC-NFS only as the primary network. Additional 32-bit network providers are not possible in this case.

Banyan VINES

If you see a message during startup that the VINES version is not the latest, edit the Vines.ini file in the Windows folder so it contains the following lines:

   [NEWREV]
   dontcopy=1
   vines.version=5.5x (x) USA      ; where x=your version
   windows.version=3.95

If you receive the message, "Vines NDIS Interface error: 1021. See NDISBAN.DOC for an error description," during startup, run the VINES utility PCCONFIG to change Banyan drivers to NDIS drivers. Also, make sure the section name matches the driver name in the Protocol.ini file.

DEC Pathworks

Windows 95 provides support for upgrading over existing DEC PATHWORKS V5.0, V5.0A and V5.1 configurations. This makes it possible to run your existing real-mode PATHWORKS components while migrating to Windows 95. However, it is strongly recommended that you upgrade to DEC's PATHWORKS for Windows 95, which contains protected-mode components.

Restrictions: PATHWORKS must be started before running Windows 95 Setup to automatically detect and upgrade PATHWORKS components. If PATHWORKS is not started or is not automatically detected, you will see startup errors when you run STARTNET. To correct this, add the appropriate "PATHWORKS V5.0 and above" protocol, using the Network icon in Control Panel.

Once a system has been upgraded to Windows 95, you cannot change your PATHWORKS configuration using PWSETUP. However, all existing template configurations present when you upgrade are converted to work under Windows 95.

PATHWORKS Native, DLC, X.25, and ISDN datalinks are converted to use an NDIS driver, if available, during the upgrade. If the replacement NDIS driver is not configured correctly or is not operating, startup will display an error and prevent loading of other PATHWORKS components.

To correct this, double-click the Network icon in Control Panel, and verify that the adapter driver is configured correctly. If any changes are made to the adapter configuration, you must remove the "PATHWORKS V5.0 and above" protocol and add it again.

PATHWORKS NetWare client licenses (CCS or FPA) are not currently supported with Windows 95. If you are using the Microsoft Client for NetWare Networks to connect to PATHWORKS for OpenVMS (NetWare) or PATHWORKS for OSF/1 (NetWare) servers, the server must have PATHWORKS FPS licenses.

Long filenames do not work correctly on PATHWORKS servers up to and including version 5.0b. You will be able to create and delete LFN files and make and remove LFN folders, but the files and folders will not appear when you use the DIR command, or when you open an Explorer window to the PATHWORKS server. PATHWORKS server version 5.00 EC01 corrects this problem and is available from DEC.

Artisoft LANtastic

The LANtastic server cannot be run when Windows 95 is setting up.

LANtastic also cannot be run in conjunction with networking support for other networks.

PRINTING TO A NETWORK PRINTER

You might have problems setting up a printer that is shared by a third- party network server. The solution is to redirect LPT1 through an MS-DOS window to the third-party share, and then use the printer setup for LPT1.

For example, if a network printer is connected to LPT1, follow these steps:

  1. At the MS-DOS prompt, type:

    net use lpt1: \\servername\sharename

    (This command might be different on the network you are using. Check the product documentation to find out how to redirect an LPT port.)

  2. Start Control Panel, double-click Printers, and then double-click Add Printer.

PROBLEMS PRINTING TO POSTSCRIPT PRINTERS OVER A NETWARE NETWORK

If you have problems when printing to a PostScript printer over a network, (error messages on the printer; no output is printed), it might be due to incorrectly configured Banner Pages. To solve this problem, you can do one of the following:

- Disable banner pages by removing the check mark from the Banner Pages

  box on the Capture printer properties (open the Printers folder, click
  the icon for the printer you are using, and then click Properties on
  the File menu);
  -or-
- Ask your network administrator to correctly configure banner pages on
  the Netware server for a PostScript printer.


ISSUES AND INSTALLATION OF MS-DLC WITH WINDOWS 95 -=========================

Windows 95 contains MS-DLC and support for installing over an existing MS-DLC or IBM-DLC installation. Setup will detect DLC and make the appropriate changes to your configuration files for these. Refer to the Windows 95 Resource Kit, Chapter 10, for a complete description of DLC support.

MICROSOFT TCP/IP PROTOCOL

If Microsoft's TCP/IP is the only protocol you have loaded on your system, the IP Address will not be added during Setup. If you have a DHCP server, open Control Panel, double-click the Network icon, and then close it. This will update the IP Address. (If you don't know if you have a DHCP server, check with your network administrator, or check if your IP address is already entered.)

If you don't have a DHCP server, start Control Panel, double-click the Network icon, double-click TCP/IP, click the IP Address tab, and then enter your IP Address.

If you are not updating from a previous Windows 95 installation (you are doing a "clean install"), to use DNS or LMHOSTS name resolution, make sure you have DNS enabled in the Network properties. To enable DNS, double-click the Network icon in Control Panel, double-click TCP/IP, click the DNS configuration tab, and then click Enable DNS.

USER PROFILES OVER THE NETWORK

If you are using user profiles over a Windows NT or Novell NetWare network, and you include Start Menu/Programs, Network Neighborhood, and/or desktop icons in your profile, the server must have long filename support to ensure that these parts of the user profile work over the network.

NETWORK BACKUP AGENTS

Arcada Backup Exec Network Backup Agent

To use the Arcada Backup Exec network backup agent included in Windows 95, you must have Arcada Backup Exec version 5.x.

Cheyenne ARCserve Network Backup Agent

To use the Cheyenne ARCserve network backup agent included in Windows 95, you must have Cheyenne ARCserve version 5.01F. You might also use earlier versions if you obtain updated NLMs from Cheyenne Software.

REAL-MODE PROTOCOLS: WARNING ICONS ON YOUR NETWORK ADAPTER

If you install a network that does not use protected-mode protocols, such as Novell Netware 3.x, you might see a yellow warning icon next to your network adapter in Device Manager. You can ignore this warning; your network is fully functional. To remove the warning icon, use the program, Extract.exe on Setup disk 1 to extract the file Ndis.vxd from your Windows 95 disks. Then, copy Ndis.vxd into your Windows\System folder. When you reboot your system, the yellow warning icon will no longer appear.

USING AN IBM THINKPAD WITH A DOCK II

If you enable 32-bit PCMCIA support, and your network cards do not appear to work properly when inserted into the Dock II's PCMCIA slots; or, if you have an ISA network card in the Dock II that has a "Code 10" error in its properties in Device Manager, call the IBM Help Center. They will provide you with a file to correct this problem.

INTEL ETHEREXPRESS PRO /100B CARD NOT CORRECTLY DETECTED

Windows 95 does not correctly detect an Intel EtherExpress Pro /100B card during Setup or hardware detection. After Setup, an entry for "PCI Ethernet controller" appears under Other Devices in Device Manager, which shows that the device is functioning properly; however, the card doesn't work.

To properly install the card, remove the PCI Ethernet controller from Device Manager, and then restart your computer. The card will then be detected; the Update Device Driver wizard will appear. Insert the driver disk that came with the card, and then click Next. The wizard will search the disk and find drivers for the Intel 82557-based PCI Ethernet. This is correct. Click Finish and the card should work.

SETTING UP A WINS SERVER

To set up a WINS server, carry out the following steps:

  1. In Control Panel, double-click the Network icon.
2. Click TCP/IP, and then click Properties. 3. Click the WINS Configuration tab. 4. Make sure that both the Primary WINS Server and Secondary WINS
   Server boxes are filled in.

   If you have only one WINS Server, you must enter the identical
   information in both the Primary WINS Server and Secondary WINS
   Server boxes.

   If you do not fill in both boxes, your WINS setting will be
   changed to Disable WINS Resolution when you restart your computer.


INTERLNK

The InterLnk networking product contained in MS-DOS 6.x does not function properly in MS-DOS mode if you are using FAT32.

USING COMSPEC VARIABLES POINTING TO NETWORK COMMAND.COM FILES

If you are on a network and are currently mapping your compspec to remote network file servers, you may get "incorrect DOS version" errors (and an explanation of the version shipping with Windows 95 version 4.00.950 B being an updated ver 7.1 etc.). You need to map the comspec to the local copy or to a compatible version on the network.


Additional query words: 95
Keywords : osr2 win95
Version : 95
Platform : WINDOWS
Issue type : kbreadme


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: December 15, 1997