Tandberg Firmware Versions Required for Windows NTLast reviewed: September 4, 1997Article ID: Q104594 |
The information in this article applies to:
SYMPTOMSThere are certain firmware revisions required for Tandberg tape drives to run with the Tandberg tape driver supplied in Windows NT version 3.1. If the firmware revision is out of date, you may receive the following error message:
Fatal translation error on tape in Drive 1. CAUSETandberg tape drives require a firmware revisions to be able to work correctly with the backup program that comes with Windows NT.
RESOLUTIONTandberg tape drives require the following revisions:
Tandberg 3660 08:15 Tandberg 3820 04:08 Tandberg 4120 04:08 Tandberg 4220 05:10There are several ways to determine the firmware revision on a Tandberg tape drive. Some models have the revision printed on the back of the unit, others do not. If it is not printed on the outside of the tape unit, it can be found on an EPROM on the inside of the unit and may take the form
966040 I04:12 92x7511where 4:12 is the firmware revision number. If you do not know the firmware revision and cannot find out what it is, please contact the manufacturer. If the firmware revision is out of date, please contact the manufacturer and update the firmware. The manufacturer can be contacted at one of the following:
Tandberg Data in Norway Kjeisasvelen 172 P.O. BOX 133 Kjelsas N-0411 OSLO, Norway Fax + 47 22 95 13 55 Phone 47 22 18 90 90 Email: vimo@tdata.no -or- Tandberg Data, INC. 2649 Townsgate Rd. Suite 600 Westlake Village, CA 91361 Phone (800) 258-8285 Fax (805) 495-4186 |
Additional query words: prodnt