Windows NT May Shut Down Immediately if Power Fails with UPS

Last reviewed: May 5, 1997
Article ID: Q105241

The information in this article applies to:
  • Microsoft Windows NT operating system version 3.1
  • Microsoft Windows NT Advanced Server version 3.1
  • Microsoft Windows NT Workstation versions 3.5, 3.51, and 4.0
  • Microsoft Windows NT Server versions 3.5, 3.51, and 4.0

SUMMARY

If you use an uninterruptible power supply (UPS) that does not have the ability to send a low battery signal to the computer, Windows NT may shut down immediately if a power failure occurs.

MORE INFORMATION

If a UPS is used that is not capable of sending a signal to the computer to inform it of a low battery condition, Windows NT instead relies on information provided by the user to determine the length of time that the system can be run on battery power. When the battery power reaches two minutes of life remaining, Windows NT begins a shutdown of the system.

When you boot Windows NT, it starts under the assumption that the battery is completely drained. This is a safety feature which assumes that a computer has just been turned on and that the UPS battery is not charged yet.

Windows NT then computes the amount of life it expects the battery to have based on the "Expected battery life" and "Battery recharge time per minute of run time" settings in the UPS Service setup screen. If, for example, the battery recharge time is set to 100 minutes, then the system must run 100 minutes for Windows NT to believe that the battery has a one minute charge. It must run 200 minutes for Windows NT to calculate a two minute charge.

Because Windows NT will begin a shutdown immediately if the power fails when the battery life is calculated to be 2 minutes or less, Windows NT may shut down immediately if the power fails and the calculated battery life is two minutes or less.

Thus, Windows NT may shut down sooner than expected after a power failure if the computer was rebooted recently, even though the UPS may be fully charged.

This behavior is expected because Windows NT assumes worst-case conditions for unattended UPS monitoring.


Additional query words: prodnt

Keywords : kbhw ntfault nthw
Version : 3.1 3.5 3.51 4.0
Platform : WINDOWS


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.