Fatal Error Message with HP 35480A DAT Drive and DPT 2022 SCSI

Last reviewed: September 21, 1994
Article ID: Q120017
The information in this article applies to:
  • Microsoft Windows NT operating system version 3.1
  • Microsoft Windows NT Advanced Server version 3.1

SYMPTOMS

An HP 35480A DAT tape backup with a DPT 2022 SCSI controller performs backups but generates this message when you try to restore or verify the backup:

   Fatal Error on Drive 1

Another tape drive and controller may restore and verify the tape with no errors.

CAUSE

This is caused by an outdated firmware revision on the DPT 2022 controller. (The HP 35480A rev 9.49 does not require a firmware update.)

RESOLUTION

Contact DPT or your hardware manufacturer for SMARTCOM BT-0002-002C5. Use it to replace SMARTCOM BT-0002-002B1. (The revision number is located on the single ROM chip in the corner of the adapter which is closest to the external SCSI connector and the EISA bus connector).


Additional reference words: prodnt 3.10
KBCategory: kbhw
KBSubCategory: nthw


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.