LPQ Command Not Supported with the HP Jet Direct Card

Last reviewed: November 9, 1994
Article ID: Q122525
The information in this article applies to:
  • Microsoft Windows NT Workstation version 3.5
  • Microsoft Windows NT Server version 3.5

The LPQ command line utility does not work when used with a Hewlett-Packard Jet Direct card. The following error message appears:

   Error: <server> did not respond correctly.

This is because the Jet Direct card does not have the ability to monitor print queues. The LPQ command will work properly with a server that has a print queue.

MORE INFORMATION

When using TCP/IP printing services, LPQ can be used to obtain the status of a print queue on a host running the Line Printer Daemon (LPD) server. The following is the syntax for the LPQ command:

   lpq  -Sserver -Pprinter [-l]

   Options:

   -S server    Name or IP address of the host providing LPD service
   -P printer   Name of the print queue
   -l           Verbose output


KBCategory: kbprint
KBSubcategory: ntutil
Additional reference words: prodnt 3.50


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.