Datarace RediModem Modem Error from RASLast reviewed: November 17, 1994Article ID: Q122901 |
The information in this article applies to:
SYMPTOMSWhen using the internal version of the Texas Instruments Datarace RediModem to dial from Remote Access, the following error message appears:
Error 651: Your modem or other connecting device has reported an error.The modem returns the following string:
<cr><lf> ERROR<cr><lf>The initialization string included in the MODEM.INF that comes with Windows NT is incorrect for the internal version of this modem.
RESOLUTIONTexas Instruments has provided a corrected MODEM.INF section for this modem. Simply copy all the lines below into the MODEM.INF file which can be found in the %SYSTEMROOT%\SYSTEM32\RAS directory.
[TI Internal - DataRace] ;Advanced features enabled, MAXCONNECT set to 38400 DEVICETYPE=modem CALLBACKTIME=10 DEFAULTOFF=compression MAXCARRIERBPS=14400 MAXCONNECTBPS=38400 <speaker_on>=M1 <speaker_off>=M0 <protocol_on>=\\N7 <protocol_off>=\\N0 <hwflowcontrol_on>=\\Q3 <hwflowcontrol_off>=\\Q0 <compression_on>=%C1 <compression_off>=%C0 <autodial_on>=ATDT <autodial_off>=ATD COMMAND_INIT=AT&F&C1&D2&N0 W1 V1 \\J0 S0=0 S2=128 S7=55<cr> COMMAND_INIT=AT<hwflowcontrol><protocol><compression><speaker><cr> COMMAND_DIAL=<autodial><phonenumber><cr> CONNECT=<cr><lf>CONNECT <carrierbps><cr><lf> COMMAND_LISTEN=ATS0=1<cr> CONNECT=<cr><lf>CONNECT <carrierbps><cr><lf> |
KBCategory: kbhw
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |