PRLNTSS.SYS Error After Applying Compaq SSDLast reviewed: September 25, 1997Article ID: Q129115 |
The information in this article applies to:
SYMPTOMSAfter you install Compaq Support Software Diskette (SSD) version 1.13 or later, a Service Control Manager error may appear indicating a service or device failed to start. The system log may contain Event ID 7022 or 7026 referencing PRLNTSS.SYS. The error may state: The following boot-start or system-start driver failed to load. Source PRLNTSS
CAUSEThis error occurs when you inadvertently install PRLNTSS.SYS when you run Compaq SETUP.CMD. PRLNTSS.SYS allows the Compaq Fast SCSI-2 controller to run the Compaq external disk array. You do not need it unless you are using an external disk array.
RESOLUTIONTo correct this problem, run Control Panel, choose Devices, and disable (stop) Compaq Proliant Storage Subsystem.
|
KBCategory: kbenv kbprb kb3rdparty
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |