SYMPTOMS

After you upgrade to Windows NT version 3.51, persistent NetWare connections are not available in File Manager. When you run NET USE from an MS-DOS Command Prompt, the NetWare connections appear as Unavailable.

CAUSE

When you use Gateway Service for NetWare (GSNW) or Client Service for NetWare (CSNW) in Windows NT version 3.5, the provider name for the NetWare network is NetWare Network. In Windows NT version 3.51, the NetWare network provider name has changed to NetWare Or Compatible Network. The provider name is stored in the user profile which precludes us from making the needed changes to allow the connections to carry over to the new version.

RESOLUTION

To correct this problem, remove the previous persistent connections and re-establish the connections again in Windows NT version 3.51.


Additional query words: prodnt gray grayed out dimmed
Keywords : kbbug3.51 kbnetwork ntinterop
Version : 3.51
Platform : WinNT


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: May 2, 1997
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.