Sun Exabyte 8500 Tape Device Requires Firmware Upgrade

Last reviewed: April 11, 1997
Article ID: Q132741
The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.5 and 3.51
  • Microsoft Windows NT Server versions 3.5 and 3.51

SYMPTOMS

After you backup data on a Sun Exabyte Model 8500 tape device and attempt to catalog tape information using Windows NT Backup (NTBACKUP.EXE), the following error message appears:

   Tape drive error detected

If more than one volume set is backed up on a tape, only the first volume set is visible during the catalog process.

RESOLUTION

To correct this problem, obtain the following from Exabyte Technical Support at (800) 445-7736 and upgrade the firmware:

   - Code Load Tape software (part number 310059-000)
   - Firmware Upgrade - 85C06X0


Additional query words: 3.5 3.51 prodnt micro systems
Keywords : kb3rdparty nthw ntutil
Version : 3.5 3.51
Platform : WinNT


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.