3C0M 3C59X.SYS Driver Fails to Initialize in Windows NT 3.51Last reviewed: May 5, 1997Article ID: Q139179 |
The information in this article applies to:
SYMPTOMSWhen you choose to Shutdown and Restart from the Windows NT 3.51 logon screen, the 3Com 3C59X.SYS driver fails to initialize the 3Com 3C590 or 3C595 network interface card (NIC). The system reboots, but when you log into Windows NT, you are notified that "a service or driver has failed to start," and the network is unavailable. The following events may also appear in the Event Log:
EVENT ID 5000: Source: El59x Type: Error Error: El59x1 : Has encountered a conflict in resources and could not load. EVENT ID 7000: Source: Service Control Manager Type: Error Error: The 3Com Fast Etherlink/Etherlink III Adapter Driver service failed to start due to the following error: A device attached to the system is not functioning. CAUSEThis problem occurs because the 3Com 3C59X.SYS driver does not reset the NIC on Windows NT shutdown. When Windows NT restarts, the driver is not able to locate the NIC.
WORKAROUNDTo work around this problem, do one of the following:
STATUS3Com Corporation is aware of this problem. For more information, contact 3Com Corporation at (800) 876-3266. The 3Com product discussed here is manufactured by 3Com Corporation, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.
|
Additional query words: prodnt 3c595 3c595-tx 3c590 dell cold boot