Errors Removing TCP/IP Registry Keys Using Insight ManagerLast reviewed: April 24, 1997Article ID: Q140987 |
3.50 3.51
WINDOWS
kb3rdparty kbsetup kbnetwork
The information in this article applies to:
SUMMARYOn Compaq file servers that are using versions of Windows NT Server that are installed using the SmartStart compact disc, a user may have difficulties reinstalling TCP/IP or other TCP/IP related services. Insight Manager is a systems management tool that provides performance and configuration management for Compaq servers and desktop clients. However, Insight Manager can complicate the process that is used to remove all traces of TCP/IP from the Windows NT registry. This article helps to identify those Insight Manager entries and prepare Windows NT Server for a trouble-free, reinstallation of TCP/IP and related components.
MORE INFORMATIONThere are many reasons why a Windows NT Server operator may need to remove and readd TCP/IP and/or the related components. Because of service dependencies that exist when these components are removed, the next time the system is booted and the operator tries to readd these components, the installation fails nevertheless with one or more of the following error messages:
If the installed TCP/IP components are from Microsoft installation media and you want to properly remove all references to the TCP/IP tools, please see the following articles in the Microsoft Knowledge Base for instructions:
ARTICLE-ID: Q122398 TITLE : TCP/IP Internetworking Components Not Available ARTICLE-ID: Q102973 TITLE : REG: TCP/IP Transport Entries, PART 1 ARTICLE-ID: Q102974 TITLE : REG: TCP/IP Transport Entries, PART 2NOTE: Q102973 and Q102974 go into greater detail regarding the TCP/IP entries in the registry. After you remove the registry entries, reinstall the TCP/IP components that are needed. If Windows NT Server was installed from the Compaq SmartStart compact disc along with the TCP/IP components, Compaq Insight Manager may also have been installed. If Insight Manager is installed and the operator has tried removing and readding TCP/IP components, they may have been able to get past the TCP/IP installation check boxes, but Setup always detects another TCP/IP component that is already installed and will prompt with "Registry Service Subkey Already Exists." causing the TCP/IP installation to fail. To successfully reinstall the TCP/IP components, any Insight Manager entries will need to be deleted from the registry. WARNING: Using Registry Editor incorrectly can cause serious, system- wide problems that may require you to reinstall Windows NT to correct them. Microsoft cannot guarantee that any problems resulting from the use of Registry Editor can be solved. Use this tool at your own risk. Insight Manager is a Compaq product. If you have questions regarding this product and the changes that it makes to the Registry, please contact Compaq Technical Support.
|
KBCategory: kb3rdparty kbsetup kbnetwork