Mkecr5xx.sys Reports Wrong I/O in Registry for SoundBlaster 16

Last reviewed: March 21, 1997
Article ID: Q141713
The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.5 and 3.51
  • Microsoft Windows NT Server versions 3.5 and 3.51

SYMPTOMS

You may experience problems reading compact discs with a CD-ROM drive connected directly to a SoundBlaster adapter if you are using Mkecr5xx.sys with the default base I/O address listed in the documentation for the adapter.

CAUSE

The base I/O address used by the SoundBlaster adapter is 10 higher than stated in the documentation for these adapters. The base I/O address can be verified by checking WinMSD or the Windows NT Registry.

RESOLUTION

Reset the base I/O address to a different setting that no other device is using. The address should be chosen so that it is free for 20 address spaces (for example, 0x320-0x33F).

STATUS

Microsoft has confirmed this to be a problem in Windows NT version 3.51. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.


Additional query words: prodnt
Keywords : kbbug3.51 kbnetwork ntsetup
Version : 3.5 3.51
Platform : WinNT


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.