OEMSETUP.INF Modifications for Automated Windows NT SetupLast reviewed: April 11, 1997Article ID: Q143134 |
The information in this article applies to:
SYMPTOMSIf you install an Original Equipment Manufacturer (OEM) network adapter in an unattended setup or a Computer Profile Setup (CPS) of Windows NT, the following error message appears:
A network card of this type is already installed in the system. Do you want to continue?"If you click OK, you may make changes or accept the network adapter configuration. If you click Continue, the following error message appears:
The dependency service or group failed to start. This error prevented the network from starting.If you click OK, the following error message appears:
The network software failed to start successfully. Choose YES to return to the Network dialog to reconfigure the software. If you choose NO to continue with the installation you will be unable to join a domain at the present time. CAUSEThe OEMSETUP.INF file for many OEM network adapters do not support unattended setup or CPS.
WORKAROUNDA few tips for customizing OEMSETUP.INF files are included below. For more information, refer to the Programmer's Guide included in the Windows NT DDK, contact Microsoft Consulting Services or contact a Solution Provider. The Enterprise Customer Unit does not support the modification of OEMSETUP.INF files. WARNING: Modification of Setup files can cause serious, system-wide problems before and after Setup and may require you to reinstall Windows NT to correct them. Microsoft cannot guarantee that any problems resulting from the modification of the Setup files can be solved. Make Setup file modifications at your own risk. To prevent user interaction during Setup, either skip the code fragments using the GOTO function or comment out code fragments by adding a semicolon (;) to the beginning of a line. You can skip code using the GOTO function. Many Network INF files in Windows NT are designed by using this method. This can be considered a solution suitable for CPS or Unattended Setup, as well as manual or interactive Setup. Make sure you understand the implications of skipping code - results in the symptoms mentioned above.
Example
installadapter = + Debug-Output "At installadapter" ; ; First, check whether the same version of the software exists ; ;; As a workaround for CPS and Unattended Setup, the below lines have ; been added: ifstr(i) $(!STF_GUI_UNATTENDED) == "YES" goto skipoptions endif NOTE: In many cases, the skipoptions section may be called nextstep. Look at your OEMSETUP.INF file to verify the appropriate section name.Commenting Out Code: Commenting out code fragments should only be considered a workaround for CPS and Unattended Setup. Subsequent manual installation or configuration of the Network adapter software may result in symptoms mentioned above. Make sure you understand the implications of commenting out code. When possible, skip code using the method described above.
Example 1
installadapter = + Debug-Output "At installadapter" ; ; First, check whether the same version of the software exists ; ;; As a workaround for CPS and Unattended Setup, the below lines are ; commented out by prepending a semicolon. ; OpenRegKey $(!REG_H_LOCAL) "" $(ProductKeyName) $(MAXIMUM_ALLOWED) KeyProduct ; Ifstr $(KeyProduct) != $(KeyNull) ; ; Same version already existed in the local machine ; Popup the dialog and ask the user whether he wants to continue ; ; CloseRegKey $(KeyProduct) ; ifstr(i) !(NTN_RegBase) == $(ProductKeyName) ; ; Cannot Install the same software again ; ; Shell $(UtilityInf), VerExistedDlg, $(ProductSoftwareTitle),+ ; $(ProductVersion) ; ifint $($ShellCode) != $(!SHELL_CODE_OK) ; Debug-Output "ShellCode error: cannot get an error string." ; goto ShellCodeError ; endif ; goto end ; else ; ; Add a new adapter card? ; ; Shell $(UtilityInf), CardExistedDlg ; ifint $($ShellCode) != $(!SHELL_CODE_OK) ; Debug-Output "ShellCode error: cannot get an error string." ; goto ShellCodeError ; endif ; ifstr(i) $($R1) != "OK" ; goto end ; endif ; set OldVersionExisted = $(TRUE) ; endif ; endif Example 2
;=================================================== ; Netcard Detection logic ; ; Check that this card's parameters can be ; fully detected. ; ;; As a workaround for CPS and Unattended Setup, the below line is ; commented out by prepending a semicolon. ; Shell $(ParamInf) Param_ParameterConfidence Ifstr(i) $($R0) != STATUS_SUCCESSFUL Debug-Output "OEMNADIN.INF: parameter confidence too low to bypass configuration" Example 3
;; As a workaround for CPS and Unattended Setup, the below lines are ; commented out by prepending a semicolon. ;=================================================== ;Display configuration dialog if confidence is too low. This is to ;provide ;the user the opportunity to verify or modify the settings manually. ; ; ui start "InputDlg" ; ifstr(i) $(DLGEVENT) == "CONTINUE" ; Set IRQValue = $(Combo1Out) ; Set IOAddrValue = $(Combo2Out) ; Set IOReadyValue = ~($(IOReadyListExt),$(Combo3Out)) ; Set IOReadyValue = ~($(IOReadyList),$(Combo3Out)) ; Set TransceiverValue = ~($(TransceiverList),$(Combo4Out)) ; ui pop 1 ; else-ifstr(i) $(DLGEVENT) == "BACK" ; set CommonStatus = STATUS_USERCANCEL ; Debug-Output "Action: exit. Bye." ; ui pop 1 ; goto end ; else ; Debug-Output "Action: unknown. Bye." ; ui pop 1 ; goto end ; endif Example 4
; Verify parameter values selected. Give the user a chance to retry ; or force the options given. ; Set from = adapteroptions Set to = skipoptions ;; As a workaround for CPS and Unattended Setup, the below lines are ; commented out by prepending a semicolon. ; Shell $(UtilityInf),RegistryErrorString,VERIFY_WARNING ; ifint $($ShellCode) != $(!SHELL_CODE_OK) ; Debug-Output "ShellCode error: cannot get an error string." ; goto ShellCodeError ; endif ; set Error = $($R0) ; Goto WarningTo retrieve adapter parameters from an answer file, you must modify the OEMSETUP.INF file. The Unattended Setup answer file is called UNATTEND.TXT. The CPS answer file is located in %SystemRoot%\SYSTEM32\DEFAULTS.INF on the distribution share.
Example
writeparameters = + Debug-Output "At writeparameters" ; ; Add the rest of the parameters to the Services area ; Ifstr(i) $(MachineType) == "MCA" set NewValueList = {{BusType,$(NoTitle),$(!REG_VT_DWORD),$(BusTypeNum)},+ {McaPosId,$(NoTitle),$(!REG_VT_DWORD),$(NETCARD_ID)},+ {SlotNumber,$(NoTitle),$(!REG_VT_DWORD),$(SlotNum)},+ {MediaType,$(NoTitle),$(!REG_VT_DWORD),1}} else Set IOAddrValue = *($(IOAddrValues), ~($(IOAddrList),$(IOAddrValue))) Shell "" DebugConfiguration "Before Writing Parameters" set NewValueList = {{INTERRUPT,$(NoTitle),$(!REG_VT_DWORD),$(IRQValue)},+ {BusType,$(NoTitle),$(!REG_VT_DWORD),$(BusInterfaceType)},+ {BusNumber,$(NoTitle),$(!REG_VT_DWORD),$(BusNumber)},+ {MediaType,$(NoTitle),$(!REG_VT_DWORD),1},+ {IoChannelReady,$(NoTitle),$(!REG_VT_DWORD),$(IOReadyValue)},+ {Transceiver,$(NoTitle),$(!REG_VT_DWORD),$(TransceiverValue)},+ {IOADDRESS,$(NoTitle),$(!REG_VT_DWORD),$(IOAddrValue)}} endif Shell $(UtilityInf), AddValueList, $(KeyParameters), $(NewValueList) ;; Following lines added for CPS or Unattended Setup ifstr(i) $(!STF_GUI_UNATTENDED) == "YES" Shell $(UtilityInf),AddDefaultNetCardParameters,$(KeyParameters) endif |
Additional query words: automate
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |