Clients Cannot Connect to Server with SysKonnect FDDI AdapterLast reviewed: May 30, 1997Article ID: Q150547 |
The information in this article applies to:
SYMPTOMSNetwork clients using the NetBEUI protocol cannot connect to a server with a SysKonnect FDDI network adapter. The client computer may display the following error message:
Error 53: The network path was not foundwhile the Server receives the following event when the SysKonnect driver is logged:
Event 5007 Timed out during an operationIf the event is logged while the server is running, other protocols (such as TCP/IP and NWLink) resume operation. If you perform a network trace, you notice that the server no longer responds to NetBIOS name resolution broadcasts.
CAUSEWhen the SysKonnect driver cannot access the FDDI ring for 15 seconds, the Event 5007 is logged and the card is reset. This is normally a hardware problem with interrupt or DMA settings or an unplugged cable. When the ring is operational again, a client using the NetBEUI protocol cannot reconnect as the driver does not re-register the NetBIOS multicast address.
RESOLUTIONPlease contact SysKonnect for an updated driver that may correct this problem.
|
Additional query words: 4.00 prodnt