Error: Thomas Conrad TC4145 Adapter Not Functioning

Last reviewed: February 2, 1998
Article ID: Q150554
3.50 3.51 WINDOWS

The information in this article applies to:

  • Microsoft Windows NT Workstation versions 3.5 and 3.51
  • Microsoft Windows NT Server versions 3.5 and 3.51

SUMMARY

After you install a Thomas Conrad TC4145 Token Ring adapter on a computer running Windows NT, the following error is returned:

   The TCC Token Ring Driver service failed to start due to the
   following error:
   The device attached to the system is not functioning.

MORE INFORMATION

This problem occurs when you use the driver supplied by Thomas Conrad with the TC4145. This is a Plug and Play (PnP) adapter, and PnP must be turned off before the driver will work properly in Windows NT. Use the QSET4145 utility supplied with the adapter--specifically, the -B=D -T=1 switches. This will turn off the PnP boot active and the PnP functionality.


KBCategory:
KBSubcategory: ntsrvwkst
Additional reference words:
Keywords : NTSrvWkst
Version : 3.50 3.51
Platform : WINDOWS


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: February 2, 1998
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.