Netflex-3: No Adapter Found When Installing SFM

Last reviewed: October 21, 1997
Article ID: Q157818
The information in this article applies to:
  • Microsoft Windows NT Workstation version 3.51
  • Microsoft Windows NT Server version 3.51

SUMMARY

If you install Services for Macintosh (SFM) on a Compaq system with a Netflex-3 adapter in Windows NT 3.51, the installation may fail with the following error:

   Setup cannot find any network adapter for Services for Macintosh. You
   will be unable to use Services for Macintosh. Try adding a network
   adapter or enable the bindings for the AppleTalk protocol.

If Services For Macintosh is currently installed and you attempt to configure SFM from the Control Panel tool, the following error message appears:

   The AppleTalk protocol registry parameters cannot be read.
   One or more parameters might be missing or contain invalid entries.

If you currently have Compaq Support Software Diskette (SSD) 1.18 installed, you may get the following error after you install SFM and restart the computer:

   Event ID 13
   No adapter is configured to be the default adapter.

CAUSE

Netflex-3 drivers installed through the Compaq SSD 1.18 do not properly set up the registry values that SFM needs for successful installation.

RESOLUTION

To work around this problem, perform one of the following:

  • Update to SSD 1.19 or later. This suggestion is recommended.
  • Modify the registry as described below:

    WARNING: Using Registry Editor incorrectly can cause serious problems that may require you to reinstall your operating system. Microsoft cannot guarantee that problems resulting from the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk.

    Remove Services for Macintosh and then make the following changes:

    1. Start Registry Editor (Regedt32.exe) and find the following registry

          location:
    

             HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet
             \Services\Cpqnf3x\Parameters
    
          where x represents the number of your adapter. It is important not to
          add the value to the Cpqnf3 key.
    
       2. From the Edit menu, click Add Value and add the following values to
          the Parameters subkey in all instances of Cpqnf3x and then click OK.
    
          Value name: MediaType.
          Data type: RegDword.
    
       3. In the Dword editor add the value: 1 Hex.
    
          NOTE: Any of the following values may apply:
             1 - Ethernet
             2 - Token Ring
             3 - ARCNet
             4 - FDDI
             5 - Apple LocalTalk
    
       4. Quit Registry Editor.
    
    
Reinstall Services for Macintosh and reapply any Windows NT service packs that were previously installed. You may then reinstall the latest SSD, before restarting your computer.


Additional query words: sfm compaq netflx netflx3 netflx3.sys
Keywords : ntmac NTSrvWkst kbnetwork
Version : WinNT:3.51
Platform : winnt


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.

Last reviewed: October 21, 1997
© 1998 Microsoft Corporation. All rights reserved. Terms of Use.