Fd8xx.sys Times Out Repeatedly with Quantum xp32150

Last reviewed: March 28, 1997
Article ID: Q158954
The information in this article applies to:
  • Microsoft Windows NT Server version 4.0
  • Microsoft Windows NT Workstation version 4.0

SYMPTOMS

When you are using a Quantum xp32150 SCSI hard disk with a Future Domain 8xx-series SCSI controller, Fd8xx.sys times out repeatedly. The system may pause and application error messages may occur.

CAUSE

An incompatibility exists between the Quantum xp32150 hard disk and the Future Domain 8xx-series controller.

RESOLUTION

Removing the xp32150 hard disk from the SCSI bus prevents the timeouts from occurring.

MORE INFORMATION

When Windows NT is installed on the Quantum hard disk, frequent timeouts can result. A demonstration of the timeouts can be performed by running Disk Administrator and attempting to detect tape devices at the same time. This can cause the system to pause for up to 10 seconds.


Additional query words: prodnt
Keywords : kbhw nthw NTSrvWkst
Version : 4.0
Platform : WinNT


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.