SET: Screen Displays "Boot 2>" Prompt After First Setup Reboot

Last reviewed: September 10, 1997
Article ID: Q163400
The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.5, 3.51, and 4.0
  • Microsoft Windows NT Server versions 3.5, 3.51, and 4.0

SYMPTOMS

When you perform a new install of Windows NT, the prompt "Boot 2>" is displayed on the screen after the reboot from text setup to GUI setup.

CAUSE

This condition can occur if the product System Commander from V Communications was previously installed on the target hard disk. This error can also appear if the master boot record code is corrupted.

WORKAROUND

There are three ways to work around this problem:

  1. Low-level format the drive.

  2. Use the System Commander uninstall.

  3. After backing up the mbr using disksave.exe, run fdisk /mbr against the system and the machine should get past this error.

STATUS

The third-party products discussed here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.


Additional query words: system commander boot 2>
Keywords : ntsetup kb3rdparty kbsetup
Version : 3.5 3.51 4.0
Platform : winnt


THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. MICROSOFT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SO THE FOREGOING LIMITATION MAY NOT APPLY.