Conner 4mm DAT Tape Devices Fail After About 30 SecondsLast reviewed: June 13, 1997Article ID: Q164462 |
The information in this article applies to:
SYMPTOMSYou have a Conner 4 mm DAT tape device and after about 30 seconds your backup application returns a hardware error.
CAUSEBecause some of the newer Conner 4mm DAT tape drives hold the busy status for more than 30 seconds, the driver assumes the device is no longer functioning. This causes the miniport driver to return an incorrect value for GetTapeStatus.
RESOLUTIONInstall the updated Tape.sys file and check with the manufacturer of your tape device that you have the latest firmware revision.
STATUSMicrosoft has confirmed this to be a problem in Windows NT version 4.0. This problem was corrected in the latest Microsoft Windows NT 4.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K |
Additional query words: 4.00 prodnt 4mm 4 mm
© 1998 Microsoft Corporation. All rights reserved. Terms of Use. |