This property specifies either the CLSID or ProgID of the event sink.
Syntax
ReplicationEventSinkConfig.CLSID[=ID]
Parameters
ID
The ProgID or CLSID of the event sink. The following ProgIDs are defined for the built-in event sinks:
CRSLocalEvents
The local OLEDB event sink.
Crssink
The local store and forward Content Deployment event sink.
The event sink for mail.
NT
The NT event sink.
Remarks
You must have Site Server Publishing administrator privileges on the server to get or set this property.
The ReplicationEventSinkConfig object can be either a user-defined event sink object or one of the installed Content Deployment event sinks, such as the OLEDB event sink or the Content Deployment event sink. You must set the CLSID property when you create your own event sink.
Example
The following example adds Project1's events to those that the NT event sink monitors and commits the change.
Option Explicit
On Error Resume Next
const CRS_ERROR_NO_MORE_ITEMS = 0&80003B17
dim ReplServer
set ReplServer = CreateObject("CrsApi.ReplicationServer")
ReplServer.Initialize("")
dim Iterator
Iterator = 0
dim EvSink
do while True
'Clear any error text
Err.Clear
'Get an event sink
set EvSink = ReplServer.EnumEventSinks(Iterator)
'Quit if empty object returned (no more instances)
if IsEmpty(EvSink) then exit do
'Quit if "No more items" error
dim ReplError
ReplError = Err.Number
if ReplError = CRS_ERROR_NO_MORE_ITEMS then exit do
dim CLSID
CLSID = EvSink.CLSID
if CLSID = "NT" then
EvSink.ProjectFilter("Project1")
EvSink.Commit
exit do
end if
Loop
'Release objects
set EvSink = Nothing
set ReplServer = Nothing
See Also