The information in this article applies to:
SYMPTOMSMicrosoft Macro Assembler (MASM) version 6.0 will incorrectly generate the following error when the sample code below is assembled:
CAUSEThis problem occurs because the segment is tagged as READONLY, and MASM treats the CMP instruction as if it modifies memory. This is incorrect behavior because the CMP instruction does not modify any memory. RESOLUTIONTo work around this problem, either remove the READONLY tag from the segment or ignore the warning when it is generated for CMP instructions. STATUSMicrosoft has confirmed this to be a problem in MASM version 6.0. This problem was corrected in MASM version 6.0a. MORE INFORMATIONThe sample code below reproduces the problem. Sample Code
Additional query words: 6.00 buglist6.00 fixlist6.00a
Keywords : |
Last Reviewed: January 5, 2000 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |