The information in this article applies to:
SYMPTOMS
When you try to create a Virtual Web Server on a computer running
Microsoft Internet Information Server (IIS) version 4.0, using the
Internet Service Manager (HTML), the interface indicates that the
information was saved with no error, but when you try to start the
Web, the following error message appears:
or a shorter message saying there is a problem with bindings. CAUSE
The above message indicates that this Web's definitions conflict
with those of an already existing Web. Analysis shows that the
Host Header Name field is now empty, even though the information
was saved in an earlier step.
WORKAROUNDTo work around this problem, use the Microsoft Management Console-based ISM, which does not exhibit this problem. RESOLUTION
If your client connection is exhibiting any of these types of
behavior, please obtain the following fix or wait for the next
Windows NT service pack.
After you apply the fix, shut down your system properly and restart it. STATUS
Microsoft has confirmed this to be a problem in Microsoft Internet
Information Server version 4.0. A supported fix is now available,
but has not been fully regression-tested and should be applied
only to systems experiencing this specific problem. Unless you
are severely impacted by this specific problem, Microsoft
recommends that you wait for the next Service Pack that contains
this fix.
Keywords : |
Last Reviewed: April 30, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |