ADSI Scripts Do Not Work Between Windows 2000 and Windows NT 4.0 Computers

ID: Q246575


The information in this article applies to:
  • Microsoft Internet Information Server 4.0
  • Microsoft Internet Information Services version 5.0


SYMPTOMS

When you attempt to use ADSI scripts on a computer running Windows 2000 to manage IIS on a computer running Windows NT 4.0, or if try to manage IIS on a Windows 2000 computer from a Windows NT 4.0 computer, the following error messages may occur:

  • From a Windows 2000 computer to a Windows NT 4.0 computer:
    0x800CC810 (MD_ERROR_IISAO_INVALID_SCHEMA)
  • From a Windows NT 4.0 computer to a Windows 2000 computer:
    0x80070003 (ERROR_PATH_NOT_FOUND)


CAUSE

Full ADSI management of IIS between different versions of Windows is not fully implemented. The errors are primarily caused by metabase-schema differences between Windows NT 4.0 and Windows 2000.


STATUS

Microsoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article.

Additional query words:

Keywords :
Version : winnt:4.0,5.0
Platform : winnt
Issue type : kbbug


Last Reviewed: January 5, 2000