Optimizing Windows 95 Independent Client for Offline Use
ID: Q183671
|
The information in this article applies to:
-
Microsoft Message Queue Server version 1.0
SYMPTOMS
If you open a queue when the computer is booted offline, the process takes
an exceptionally long time.
CAUSE
There is a bug in Microsoft Message Queue Server version 1.0 Independent
Client for Windows 95 which involves remote procedure call (RPC) timeouts.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Message Queue
Server Systems Management Server version 1.0. We are researching this
problem and will post new information here in the Microsoft Knowledge Base
as it becomes available.
WORKAROUND
You can create a dual boot configuration as a workaround for this problem.
To create a dual boot configuration on a computer running Windows 95,
perform the following steps:
- In Control Panel, double-click the System icon, and then click the
Hardware Profiles tab.
- Click the hardware profile that you are currently using, and then click
Copy.
- Type "No Network" in the To box, and then click OK.
- Click the Device Manager tab.
- Double-click Network Adapters and then double-click your network adapter
card icon.
- In the Device Usage box click to clear the "No Network" checkbox. This
prevents the network drivers from loading when this profile is used.
- Click OK and exit Control Panel.
- Restart Windows 95. When Windows 95 restarts, you will be prompted to
select the configuration to use. Select "No Network".
NOTE: Microsoft Message Queue Server Custom application messages must be
set with MQMSG_DELIVERY_RECOVERABLE. This allows the messages to be written
to disk and survive a memory re-cycle.
Additional query words:
Keywords : kbbug1.00 MQQueue
Version : winnt:1.0
Platform : winnt
Issue type : kbbug