ODBC Logging Fails Without Warning

ID: Q177707


The information in this article applies to:
  • Microsoft Proxy Server version 2.0


SYMPTOMS

When you are configured to log to an ODBC datasource, your requests will fail to be logged without warning if the table name specified is incorrect.


CAUSE

If the table name is invalid, does not exist, or is not in the proper format, no logging will take place. The user will not be warned that the ODBC properties were incorrectly configured or that the table structure is incorrect.


RESOLUTION

Verify that the table name is specified correctly in the ODBC logging properties of Web or Winsock Proxy properties.

Also, ensure that the table structure is in the correct format. Proxy 2.0 Setup program provides a SQL Server script to create the table structure for Web Proxy, Winsock Proxy, and Packet Filter logging. They are located in the following directories:


   Drive:\%Winnt%\Help\Proxy\Misc\Msp.sql (Web and Winsock logging)

   Drive:\%Winnt%\Help\Proxy\Misc\Pf.sql (Packet Filter logging) 

Additional query words: odbc logging proxy

Keywords : pxsconfig
Version : WINNT:2.0
Platform : winnt
Issue type : kbprb


Last Reviewed: August 10, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.