The information in this article applies to:
SYMPTOMSIf you open Performance Monitor, and you open counters on a remote Microsoft Personalization System (MPS) server, and then save the workspace, quit Performance Monitor, open Performance Monitor, and try to load the workspace, workspace will experience an access violation (AV). STATUSMicrosoft has confirmed this to be a problem in Microsoft Commercial Internet System version 1.0. This problem has been corrected in the latest U.S. Service Pack for Microsoft Commercial Internet System version 1.0. For information on obtaining the Service Pack, query on the following article in the Microsoft Knowledge Base: Q183062 MCIS 1.0 Service Packs 1 and 2 Information MORE INFORMATIONTwo variables were incorrectly set in the code. The two files that need to be updated, Smail.dll, and Ssovote.dll, have been corrected and are in Service Pack 1 (SP1). Additional query words:
Keywords : |
Last Reviewed: January 19, 2000 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |