CRS: Webadmin Cannot Take a Project Name Containing a Space

ID: Q176514


The information in this article applies to:
  • Microsoft Commercial Internet System version 1.0
  • Microsoft Site Server version 2.0


SYMPTOMS

The Content Replication System (CRS) Webadmin cannot start a project name that has a space in it; if the name contains a space, you receive the following error message:

crpr.pgi (46): error 8004005:unspecified error
crpr.pgi (46): error 80020005: type mismatch


WORKAROUND

To work around this problem, do either of the following:

  • Do not use a space in the project name.


  • -or-

  • Use CRS from a command prompt to start the project, as in the following example:
    CRS startrep "<project_name>" /display
    NOTE: The quotation marks around the project name are required.


Additional query words: quote mark fail nmdcrs

Keywords : kbusage kbbug1.00 kbbug2.00 CommMisc
Version : winnt:1.0,2.0
Platform : winnt
Issue type : kbprb


Last Reviewed: January 19, 2000
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.