The information in this article applies to:
SYMPTOMSWhen you send more than 256 characters in a form field to the Posting Acceptor along with a file of any size, the data that is retrieved from the form values and posted using WinInet, and the "repost" appears to be corrupted. CAUSEA hard-coded buffer is being overrun. RESOLUTIONTo resolve this problem, obtain the latest service pack for Site Server 3.0. For additional information, please see the following article in the
Microsoft Knowledge Base: Q219292 How to Obtain the Latest Site Server 3.0 Service Pack STATUSThis problem was first corrected in Site Server 3.0 Service Pack 3. MORE INFORMATIONA buffer is now dynamically allocated based on the length of the string entered in the form field. Additional query words:
Keywords : SS3SP3Fix |