Usage Analysis Import History Manager Produces a "Run-time error. '6': Overflow" Warning

ID: Q241014


The information in this article applies to:
  • Microsoft Site Server version 3.0
  • Microsoft Site Server version 3.0, Commerce Edition


SYMPTOMS

When attempting to use Site Server 3.0 Usage Analysis Import History Manager in the Usage Import module, the following warning dialog box appears:

Microsoft Site Server Analysis
Run-time error. '6':
Overflow
OK
When you click OK, the program exits.


CAUSE

More than 2519 logs have been imported into Usage Import. Internally, Import History Manager is multiplying the number of logs imported by two other large numbers. The product exceeds the maximum value for an integer.


RESOLUTION

To resolve this problem, obtain the latest service pack for Site Server 3.0. For additional information, please see the following article in the Microsoft Knowledge Base:

Q219292 How to Obtain the Latest Site Server 3.0 Service Pack


STATUS

This problem was first corrected in Site Server 3.0 Service Pack 3.


MORE INFORMATION

Additional query words:

Keywords : SS3SP3Fix
Version : winnt:3.0
Platform : winnt
Issue type : kbbug


Last Reviewed: October 26, 1999