Usage Import Reports Automation Errors for Large Number of Query Parameters

ID: Q252621


The information in this article applies to:
  • Microsoft Site Server version 3.0


SYMPTOMS

Usage Import may report an Error 7 "Out of memory" and an "Automation Error" during import.


CAUSE

Input log entries with more than 128 query parameters per request cause the import process to end.


WORKAROUND

To work around this problem, remove all IIS log entries with more than 128 parameters per request.


RESOLUTION

A supported fix that corrects this problem is now available from Microsoft, but it has not been fully regression tested and should be applied only to systems experiencing this specific problem. If you are not severely affected by this specific problem, Microsoft recommends that you wait for the next Site Server service pack that contains this fix.

To resolve this problem immediately, contact Microsoft Product Support Services to obtain the fix. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web:

http://www.microsoft.com/support/supportnet/overview/overview.asp
The English version of this fix should have the following file attributes or later:

   Date        Time    File Version   Size      File name   Platform
   ---------------------------------------------------------------------
   01/18/2000  10:57a  7.0.1285.0       674,800 Uas.exe     x86
   01/18/2000  10:56a  7.0.1285.0     1,303,824 Uas.exe     alpha 


STATUS

Microsoft has confirmed this to be a problem in Site Server 3.0.

Additional query words:

Keywords :
Version : winnt:3.0
Platform : winnt
Issue type : kbbug


Last Reviewed: January 28, 2000
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.