SMS Remote Control Fails if Not Enough LANAs are Available
ID: Q121658
|
The information in this article applies to:
-
Microsoft Systems Management Server version 1.0
SYMPTOMS
Help Desk and Diagnostics fail from the Systems Management Server Admin
user interface (UI) if the protocol binding needed is greater than the
number of default LANAs in the Windows NT Registry. For example, if the
LANA number for the binding is 5 and the Registry only shows default for 4
LANAs, the UI attempts the command but fails.
RESOLUTION
To correct this problem:
WARNING: Using Registry Editor incorrectly can cause serious, system-wide
problems that may require you to reinstall Windows NT to correct them.
Microsoft cannot guarantee that any problems resulting from the use of
Registry Editor can be solved. Use this tool at your own risk.
- Run Registry Editor (REGEDT32.EXE).
- From the HKEY_LOCAL_MACHINE subtree, go to the following key:
\SOFTWARE\Microsoft\SMS\Components\SightNT\Lana
- Add the Default entries for the needed LANAs. For example, from the
Edit menu, choose Add Value. Enter values for the following:
Value Name: Default# (where # is the next LANA number)
Data Type: REG_DWORD
Data: (Enter the LANA number you are adding, in Hex)
- Choose OK and quit Registry Editor.
- Quit Systems Management Server Admin and restart Systems Management
Server.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server
version 1.0. This problem was corrected in Systems Management Server
version 1.1.
In Systems Management Server version 1.1, seven lanas are scanned by
default.