The information in this article applies to:
SYMPTOMSWhen you run NET LOGON on a LAN Manager client from the AUTOEXEC.BAT file, and an SMSLS.BAT file exists in the client's logon script, SETLS16.EXE cannot find the WIN.INI file pointed to by the SMSLS.INI file on the logon server. This causes inventory to be reported to the logon server's Systems Management Server site instead of the domain/site pointed to by the [SMS] section in the WIN.INI file. CAUSE
SETLS16 looks for the WINDIR environment variable and from that determines
the location of WIN.INI. This fails because WINDIR doesn't exist yet when
you execute the logon script. This is true regardless of the current
directory the user is in. Putting WIN.INI in drive C allows this to work.
Logging on to the domain from within Windows works.
WORKAROUND
Do one of the following to work around this problem:
-or- STATUSMicrosoft has confirmed this to be a problem in Systems Management Server versions 1.0 and 1.1. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: sms prodsms Win16 resource master
Keywords : kbnetwork kbbug1.00 NTInterop smsinv kbbug1.10 |
Last Reviewed: December 13, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |