The information in this article applies to:
SYMPTOMSWhen you install a primary site, Systems Management Server Setup limits the length of the path for the location of the database and log devices. The text field for the path does not scroll and the computer beeps when the limit is reached. The total number of characters allowed for the path depends on the width of the character used (and may be fewer than 40 characters). WORKAROUNDTo work around this problem, create the database and log devices using the Microsoft SQL Administrator utility. This method requires the user specifies only the database device name and the log device name, rather than the full path of the database and log devices. STATUSMicrosoft has confirmed this to be a problem in System Management Server version 1.0. This problem was corrected in Systems Management Server version 1.1. Additional query words: prodsms sms
Keywords : kbnetwork kbbug1.00 ntsetup ntconfig kbfix1.10 smsdatabase |
Last Reviewed: December 14, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |