SMS Remote Control Fails on AST Manhattan Pentium

ID: Q130900


The information in this article applies to:
  • Microsoft Systems Management Server version 1.0


SUMMARY

If you remove Remote Control for the second time from a Windows for Workgroups 3.11 client using a 3COM 3C503 or 3C509 network interface card (NIC), the following error message may appear:

An application error has occurred and an application error log is being generated.

exe\SMS.DBG (pid=33)
Exception: access violation (0xc0000005), Address <Hex address>
This problem occurs when Systems Management Server is installed on an AST Manhattan Pentium computer with 64 megabytes of RAM.

To work around this problem, do one of the following:

  • Use another supported NIC on the Windows for Workgroups client.


  • -or-

  • On the Systems Management Server, reduce the RAM to 16 MB.


Additional query words: prodsms sms mb

Keywords : kbnetwork smsgeneral
Version : winnt:1.0
Platform : winnt
Issue type : kbprb


Last Reviewed: December 14, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.