CLI_DOS.EXE Err Msg: Unable to Rename UID File...

ID: Q153635


The information in this article applies to:
  • Microsoft Systems Management Server versions 1.0, 1.1


SYMPTOMS

When you run RUNSMS.BAT from a NetWare client computer, the following Client Setup (CLI_DOS.EXE) error message appears:

Unable to Rename UID File... Trying Next UID
NOTE: The problem does not occur when CLI_DOS.EXE is called from a NetWare login script (SMSLS.SCR).


CAUSE

When you run CLI_DOS.EXE in SMSLS.SCR, the /P parameter is set to VOL:/path/LOGON.SRV/. However, when you run RUNSMS.BAT, the /P parameter is set to SRV/VOL:/path/LOGON.SRV/.


STATUS

Microsoft has confirmed this to be a problem in Systems Management Server versions 1.0 and 1.1. This problem has been corrected in Systems Management Server version 1.2.

Additional query words: prodsms UID novell volume

Keywords : kbsetup smssetup kbbug1.10 kbfix1.20
Version : winnt:1.0,1.1
Platform : winnt
Issue type :


Last Reviewed: December 16, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.