The information in this article applies to:
SYMPTOMS
Remote Control utilities and Remote Diagnostics will fail to connect to 16-
bit SMS clients if the machine name contains extended characters.
Extended characters are those beyond the first 127 in the ASCII character
set. CAUSEWhen a client has extended characters in its name, it registers the name on the network as an OEM string. The Windows NT NetBIOS interface expects an ANSI string, and Sightnt.dll uses ANSI strings for remote control. WORKAROUNDChange the machine name. NetBIOS names can contain characters between ASCII 33 and 126 inclusive except for the MS-DOS reserved characters such as the backward and forward slashes, braces ({}), the greater than and less than signs, and so forth. STATUSMicrosoft has confirmed this to be a problem in Systems Management Server versions 1.0, 1.1, and 1.2. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: prodsms helpdesk RC win16 win95 msdos
Keywords : kbusage kbbug1.00 smsremtshoot kbbug1.10 kbbug1.20 |
Last Reviewed: January 12, 2000 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |