The information in this article applies to:
SYMPTOMSA computer running Windows NT Server running the Systems Management Server Inventory Agent either as a service or as an executable may generate the following Blue Screen STOP message during the hardware inventory phase:
NOTE: This message was generated by a computer running Windows NT Server
3.51 Service Pack 5.
This problem is specific to the IBM PCI Token Ring Card 16/4, reference 75H9800, or 75H9802, using the following driver:
WORKAROUNDTo work around this problem, obtain a new version of the Ibmtrp.sys driver from IBM at the following location:http://www.networking.ibm.com/nes/nestoken.htmDownload the following image (PCI Token Ring Adapter family):
The updated driver is dated 11/04/96, and its size is 90,944 bytes. Any
version of the driver dated before this date causes the error to occur.
Additional query words: prodnt prodsms 0xA
Keywords : kb3rdparty kbenv smsinv |
Last Reviewed: September 3, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |