The information in this article applies to:
SYMPTOMS
When trying to install the Systems Management Server client from a Systems
Management Server logon server running InocuLAN for Windows NT Server
version 4.0, the Systems Management Server client setup may fail. The
client will receive the error message, "Unable to read unique
identification file (*.UID) ....trying". The message will appear about 15
times, then client setup will fail.
CAUSEThe problem is caused by a combination of the Netflex 3 adapter driver and InocuLAN for Windows NT Server version 4.0. This combination produces redirector timeout errors on the Netflex 3 adapter.WORKAROUNDTo work around this problem, stop the InocuLAN service running on the Systems Management Server logon server.MORE INFORMATIONThis problem has been observed primarily on Compaq servers using the configuration described above. However, the same problem has occurred on other hardware configurations as well.To correct the problem, obtain the latest version of InocuLAN for Windows NT Server version 4.0 from Cheyenne Software (build 241 or later). Additionally, if a Compaq server is involved, contact Compaq technical support and apply the latest SSD for the server configuration, SSD version 1.2c or later. The product discussed here, InocuLAN 4.0, is manufactured by Cheyenne Software, a manufacturer independent of Microsoft. We make no warranty, implied or otherwise, regarding this products' performance or reliability. Additional query words: prodsms anti-virus virus clisetup innoculan
Keywords : kb3rdparty kbnetwork smssetup smsinv |
Last Reviewed: September 2, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |