The information in this article applies to:
SYMPTOMSThe Systems Management Server Remote Control agent (Wuser32.exe) shows a memory leak on systems using a 3COM 3C590 or 3C905 network adapter card with bus mastering enabled. A large number of page file bytes are consumed and not released, which eventually results in virtual memory errors, and may cause the system to stop responding. The problem does not occur if bus mastering is disabled on the 3C590 adapter. However, there is no option to disable bus mastering on the 3C905 adapter. WORKAROUND
To work around this problem, do any of the following:
Q141299 Disabling Bus Mastering On 3Com 3C590 PCI Network Cards STATUSMicrosoft has confirmed this to be a problem in Systems Management Server version 1.2. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: prodsms wuser32 sms interface
Keywords : kbnetwork smsremtshoot kbbug1.20 |
Last Reviewed: September 1, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |