The information in this article applies to:
SYMPTOMSWhen you use the Remote Reboot feature of Systems Management Server on a client computer running Windows 95 OEM Service Release 2 (OSR2), the following message is displayed during the restart:
CAUSERemote Reboot issues a CPU reset instruction, not a graceful shutdown. STATUSMicrosoft has confirmed this to be a problem in Systems Management Server versions 1.1 and 1.2. This problem has been corrected in the latest U.S. service pack for Systems Management Server version 1.2. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
WORKAROUND
To work around this problem, do any one of the following:
MORE INFORMATIONWindows 95 OSR2 includes versions of the Io.sys and Win.com files that check the Clean Shutdown and Hard Disk Error bits in the Virtual File Allocation Table (VFAT) during startup. If either of these bits is enabled (that is, cleared to 0) on any drive present in real mode, you are prompted to run ScanDisk. If you do not press a key within 60 seconds, ScanDisk runs anyway. Additional query words: prodsms osr windows95 win95 win original equipment manufacturer
Keywords : smsremtshoot kbfix1.20.sp4 kbbug1.10 kbbug1.20 |