The information in this article applies to:
SYMPTOMSUnder specific circumstances, when you attempt to upgrade a secondary site, the upgrade may fail because of timing-related issues. This may occur in environments where there are several secondary site servers under the central site, and each secondary site has numerous logon servers. CAUSE
During a secondary site upgrade process, the Upgrade Bootstrap Service is
delivered to the secondary site server and started. This issues a site
shutdown using a SHUTDOWN.CT1.
The secondary site never upgrades, it simply goes into an Emergency Restart after 48 hours. WORKAROUNDTo work around this problem, force an upgrade of the secondary site from its parent site using the PREINST Command:
STATUSMicrosoft has confirmed this to be a problem in Microsoft Systems Management Server version 1.2. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: prodsms
Keywords : smssetup kbbug1.20 smshierman smssiteconfigman |