SMS: PGC Fails to Configure Shared Applications on Windows for Workgroups Clients

ID: Q191342


The information in this article applies to:
  • Microsoft Systems Management Server version 1.2 Service Pack 2 and later


SYMPTOMS

After applying Systems Management Server 1.2 Service Pack 2 or later, the updated Appsta16.exe file fails to run the configuration command line for shared applications that have the option "Runs with UNC Name" selected.

This version of Appstart.exe is only used on client computers running Windows 3.1 or Windows for Workgroups 3.11. They normally receive the following error:

Cannot configure <app name>. Cannot obtain the configuration program name.
It is also possible for different errors to occur as well.


WORKAROUND

To work around this problem, do either of the following:

  • Configure the shared application to run with a drive letter and not a UNC connection.


  • -or-

  • Copy all of the files used by the configuration command line to the SMS\Site.srv\Maincfg.Box\MStest directory. This may not always be a very desirable solution if the configuration requires a large number of files.



STATUS

Microsoft has confirmed this to be a problem in Systems Management Server version 1.2. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.

Additional query words: prodsms sp sp2 setup fails program group control

Keywords : kbbug1.20.sp3 smspgc kbbug1.20.sp2
Version :
Platform : winnt
Issue type : kbbug


Last Reviewed: December 16, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.