SMS: Missing Records in WorkstationStatus Table Generate Badmif
ID: Q199729
|
The information in this article applies to:
-
Microsoft Systems Management Server version 1.2
SYMPTOMS
If, for an undetermined reason, there is no existing record in the WorkstationStatus table when dataloader attempts to load a MIF, the MIF will be moved to the Badmifs directory. The following appears in the datalodr.log: (This example shows SQL tracing enabled.)
> Updating No-History group: MICROSOFT|WORKSTATION_STATUS|1.0...
> SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM 126
> SQL>>> select 'X' from WorkstationStatus where datakey = 47471
> SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM 126
> SQL>>>>> Done. SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM
> 126
> QL>>> insert into WorkstationStatus (Files_Not_Installed0,
> System_Files_Not_Modified0, LastHWScan, LastSWScan,
> Failed_Hardware_Checks0, Standalone_Workstation0, datakey, ComponentName)
> values ("None", "None", "19981223 12:50:37", "19981223 12:50:38", "None",
> "No", 47471, "Workstation") SMS_INVENTORY_DATA_LOADER 12/23/98
> 1:03:02 PM 126
> SQL>>>>> Done. SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM
> 126
> CMachineDataTable::AddToMachineDataTable - entry already in table
> SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM 126
> CGroup::ProcessNoHistoryGroup - couldn't insert new group data
> SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM 126
> finished processing current machine. SMS_INVENTORY_DATA_LOADER
> 12/23/98 1:03:02 PM 126
> Cannot process MIF X00000007.MIF, moving it to BADMIFS
> SMS_INVENTORY_DATA_LOADER 12/23/98 1:03:02 PM
WORKAROUND
Two options are available to work around this problem:
- The badmifs exhibiting this particular problem can be moved back to the process directory. Dataloader will process them correctly the second time.
- The badmifs exhibiting this particular behavior could be deleted (the information will be lost), and the next inventory cycle should process properly.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server version 1.2.
Additional query words:
prodsms hinv32 smssql
Keywords : kbDatabase kbSMS120bug kbDataLoader
Version : winnt:1.2
Platform : winnt
Issue type : kbbug