SMS: Supported Naming Conventions for NDS Logon Point Creation

ID: Q201802


The information in this article applies to:
  • Microsoft Systems Management Server version 2.0


SUMMARY

For a Systems Management Server 2.0 site to successfully create a client access point (CAP) and logon point on a NetWare Directory Services (NDS) volume, there are certain naming conventions that must be followed. This article documents the required naming conventions.


MORE INFORMATION

Tree Names

The following apply to tree names:
  • The NDS tree can contain up to 32 ASCII characters. Accepted characters are a-z, A-Z, 0-9, hyphen ("-"), and the underscore ("_").


  • The NDS tree can NOT start or end with an underscore character, nor can it contain two consecutive underscores (__).


  • The NDS tree name can NOT contain any spaces.


Container and Volume Names

The following apply to container and volume names:
  • They may not contain any of the following:

    • Slashes ("/")


    • Backslashes ("\")


    • Colons (":")


    • Commas (",")


    • Asterisks ("*")


    • Question marks ("?")




  • Object names are NOT case-sensitive.


Distinguished Names

The following apply to distinguished names:
  • Distinguished names MUST contain an Organization (O); this is the top level of the Systems Management Server tree.


  • Use of the Country (C) in distinguished names is optional. If the C is used, it cannot be longer than two characters.



The third-party products discussed here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Additional query words: prodsms nwroles

Keywords : kbNDS kbNovell
Version : winnt:2.0
Platform : winnt
Issue type : kbinfo


Last Reviewed: February 19, 1999