Multiple SMS 2.0 sites cannot use the same NetWare Bindary Servers and NetWare NDS servers as logon points. SMS NW Logon Server Manager detected that NetWare bindery server "<SERVERNAME>" is already being used as an SMS Logon Point by another SMS site. Solution: Only one SMS site should be configured to use server "<SERVERNAME>" as an SMS Logon Point. Using the SMS Administrator console, remove this server from the list of Logon Points used for the SMS NetWare Bindery Logon Discovery and Installation methods, either for this site or the site that is currently using this server as an SMS Logon Point. MORE INFORMATIONMicrosoft has confirmed this to be a problem in Systems Management Server version 2.0. Additional query words: prodsms netware nw logon point nds