SMS: Smscfg.cpl May Not Be Loaded with More Than 20 Network Adapters

ID: Q240980


The information in this article applies to:
  • Microsoft Systems Management Server versions 2.0, 2.0 SP1


SYMPTOMS

When you double-click the SMS tool in Control Panel, you may receive the following error message:

An error occurred while Windows was working with the Control Panel file SMSCFG.CPL


CAUSE

This error message can occur if the SMS client has more than 20 network adapters (physical or virtual/dial-up adapters). One type of server that may have more than 20 network adapters is the 3Com EdgeServer.


RESOLUTION

A supported fix that corrects this problem is now available from Microsoft, but it has not been fully regression tested and should be applied only to systems experiencing this specific problem. If you are not severely affected by this specific problem, Microsoft recommends that you wait for the next Systems Management Server service pack that contains this fix.

To resolve this problem immediately, contact Microsoft Product Support Services to obtain the fix. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web:

http://www.microsoft.com/support/supportnet/overview/overview.asp
The English-language version of this fix should have the following file attributes or later:

   Date      Time   Version      Size   File name      Platform
   ------------------------------------------------------------
   08/26/1999 10:00p              64,560 Smscfg.cpl    Intel
   07/29/1999 03:46p             336,736 Mslmclin.dll  Intel
   08/06/1999 11:53a             256,864 Bindclin.dll  Intel
   08/06/1999 11:53a             266,592 Ndsclin.dll   Intel
   08/26/1999 10:06p           3,210,707 Clicore.exe   Intel
   08/26/1999 10:07p                  67 Compver.ini   Intel
   08/26/1999 10:01p             110,352 Smscfg.cpl    Alpha
   07/29/1999 03:46p             576,272 Mslmclin.dll  Alpha
   08/26/1999 09:59p           4,233,686 Clicore.exe   Alpha
   08/26/1999 10:08p                  67 Compver.ini   Alpha 
Note that the Smscfg.cpl file (Alpha and Intel) is included separately with this hotfix for reference only. You do not need to apply this file to your site server because it is contained within the Clicore.exe file. Follow the instructions below to cause your SMS clients to receive all the necessary updated files.

NOTE: Due to file dependencies, the most recent hotfix or feature that contains the above files may also contain additional files.



STATUS

Microsoft has confirmed this to be a problem in Systems Management Server version 2.0.


MORE INFORMATION

To install the hotfix:

  1. Stop the SMS_SITE_COMPONENT_MANAGER and SMS_EXECUTIVE services.


  2. Copy the updated Compver.ini file to the Inboxes\Clicomp.src\Base folder.


  3. Copy the hotfixed Clicore.exe file to the Inboxes\Clicomp.src\Base\Platform folder.


  4. Copy the updated Mslmclin.dll, Ndsclin.dll, and Bindclin.dll files to the SMS\Bin\Platform folder.

    NOTE: for Alpha, only one file, Mslmclin.dll, is included with this fix--this is normal.


  5. Start the SMS_SITE_COMPONENT_MANAGER and SMS_EXECUTIVE services.


The default Client Configuration Installation Manager (CCIM) polling interval is 23 hours. Therefore, it may take up to 23 hours for the hotfixed files to be propagated to the clients. To speed up this process, you can stop and restart the SMS Client Service on each client. You can also create a software distribution for one of the Resource Kit tools (Setevnt.exe or Cliutils.exe), along with the appropriate parameter(s) to start a CCIM work cycle. For information about the proper syntax to use with these tools, see the Resource Kit documentation.

Additional query words: prodsms edge server ras dialin dialout dialup modem pool

Keywords : kbSMS120 kbSMS120bug
Version : winnt:2.0,2.0 SP1
Platform : winnt
Issue type : kbbug


Last Reviewed: September 15, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.